Data Centers How Green is Your Data Center?
Give us your opinions and experiences designing and implementing the green data center
By: John Savageau
Oct. 18, 2009 08:45 AM
Data Center “X” just announced a 2 MegaWatt expansion to their facility in Northern California. A major increase in data center capacity, and a source of great joy for the company. And the source of potentially 714 additional tons of carbon introduced each month into the environment.
If you do a “Bing” search won the topic of “green data center,” you will find around 144 million results. Three times as many as a “paris hilton” search. That makes it a fairly saturated topic, indicating a heck of a lot of interest. The first page of the Bing search gives you a mixture of commercial companies, blogs, and “ezines” covering the topic – as well as an organization or two. Some highlights include:
With this level of interest you might expect just about everybody in the data center industry to be aggressively implementing “green data center best practices.” Well, not really. In the past month the author (me!) toured not less than six commercial data centers. In every data center I saw major best practices violations, including:
And other more complicated issues such as not integrating the electrical and environmental data into a building management system. The Result of Poor Data Center Management Most data centers today consider a target value of 1.5 good, with some companies such as Google trying to drive their PUE below 1.2 – an industry benchmark. Other data centers are not even at the point where they can collect meaningful PUE data. The previous Google link has an extended description of data collection methodology, which is a great introduction to the concept. The Uptime Institute of course has a large amount of support materials. And a handy Bong search reveals another 995,000 results on the topic. No reason why any data center operator should be in the dark or uniformed on the topic. So let’s use a simple PUE example and carbon calculation to determine the effect of a poor PUE: Let’s start with a 4 MW data center. The data center currently has a PUE of 3.0, meaning of the 4 MW of power consumed within the data center 3MW are consumed by support materials, and 1MW by actual IT equipment. In California, using the carbon calculator, this would return 357 tons of carbon produced by the IT equipment and 1071 tons of carbon produced by support equipment such as air conditioning, lights, poorly maintained electrical equipment, etc., etc., etc… 1071 tons of carbon each month, possibly generated by waste which could be controlled through better design, management, and operations in our data centers. Most commercial data centers are in the 4~10MW range. Scary. The US Department of Energy recently did an audit entitled “Department of Energy Efforts to Manage Information technology in an Energy-Efficient and Environmentally Responsible Manner,” which highlights the fact even tightly regulated agencies within the US Government have ample room for improvement. “We concluded that Headquarters programs offices (which are part of the Department of Energy’s Common Operating Environment) as well as field sites had not developed and/or implemented policies and procedures necessary to ensure that information technology equipment and supporting infrastructure was operated in an energy-efficient manner and in a way that minimized impact on the environment.” (OAS-RA-09-03) What Can We Do? If your data center requires security cameras 24×7, consider using dual-mode cameras that have low light vision capability. Place blanking panels in all cabinets. Considering removing all open racks from your data center unless you are using them for passive cabling, cross-connects, or very low power equipment. Consider using hot or cold aisle containment models for your cabinet lineups. Lots of debate on the merits of hot aisle containment vs. cold aisle containment, but the bottom line is that cool air going into a server makes the server run better, reduces the electrical draw on fans, and increases the value of every watt applied to your data center. Consider this – if you have 10 servers using a total of 1920 watts (120v with a 20 amp breaker <at 16 amps draw>), that gives you the potential of running those 10 servers at full specification draw. That includes internal fans which start as needed to keep internal components cool enough to operate within equipment thresholds. If the server is running hot, then you are using your full 192 watts per server. If the server is running with cool air on the intake side, no hot air recirculation producing heat on the circuit boards, then you can reasonably expect to reduce the electrical draw on that component. If you are able to reduce the actual draw each server consumes by 30~40% by removing hot air recirculation and keeping the supply side cool, then you may be able to add additional servers to the cabinet and increase your potential processing capacity for each breaker and cabinet by another 30~40%. This will definitely increase your efficiency, cost you less in electricity and power, give you additional processing potential. Sources of Information The Bing search will give you more data than you will ever be able to absorb, however the good news is that it is a great way to read through individual experiences, including both success stories and horror stories. Learn through other’s experiences, and start on the road to both reducing your carbon footprint, as well as getting the most out of your data center or data center installation. Give us your opinions and experiences designing and implementing the green data center – leave a comment and let others learn from you too! John Savageau, Long Beach ![]() Reader Feedback: Page 1 of 1