yourfanat wrote: I am using another tool for Oracle developers - dbForge Studio for Oracle. This IDE has lots of usefull features, among them: oracle designer, code competion and formatter, query builder, debugger, profiler, erxport/import, reports and many others. The latest version supports Oracle 12C. More information here.
Cloud Expo on Google News
Cloud Expo & Virtualization 2009 East
Smarter Business Solutions Through Dynamic Infrastructure
Smarter Insights: How the CIO Becomes a Hero Again
Windows Azure
Why VDI?
Maximizing the Business Value of Virtualization in Enterprise and Cloud Computing Environments
Messaging in the Cloud - Email, SMS and Voice
Freedom OSS
Stairway to the Cloud
Sun's Incubation Platform: Helping Startups Serve the Enterprise
Cloud Computing & Enterprise IT: Cost & Operational Benefits
How and Why is a Flexible IT Infrastructure the Key To the Future?
Click For 2008 West
Event Webcasts
Scatter Radiation from Mammography Presents No Cancer Risk

CHICAGO, Nov. 27, 2012 /PRNewswire-USNewswire/ -- The radiation dose to areas of the body near the breast during mammography is negligible, or very low, and does not result in an increased risk of cancer, according to a study presented today at the annual meeting of the Radiological Society of North America (RSNA). The results suggest that the use of thyroid shields during mammography is unnecessary.

"Thyroid shields can impede good mammographic quality and, therefore, are not recommended during mammography," said Alison L. Chetlen, D.O., assistant professor of radiology at Penn State Hershey Medical Center.

During mammography, some X-rays scatter away from the primary beam in the breast and spread outward in different directions. Although this scatter radiation is much weaker than the primary beam, there has been concern that women exposed to it during mammography could face an increased risk of cancer, especially in radiosensitive areas like the thyroid gland.

To better understand the potential impact of scatter radiation, Dr. Chetlen and colleagues set out to measure the dose received by the thyroid gland, salivary gland, sternum, uterus and the lens of the eye during screening digital mammography. Each of the 207 women in the study group wore six optically stimulated luminescent dosimeters -- a device used to measure an absorbed dose of ionizing radiation -- while undergoing two-view screening mammography.

Analysis of the dosimeters by a medical physicist immediately after the exam revealed that the doses to the various areas outside of the breast ranged from negligible to very low.

Absorbed radiation dose is measured in a unit called a milligray (mGy). The average estimated organ dose to the salivary gland was 0.05 mGy. The average estimated organ dose to the thyroid gland was 0.05 mGy. These doses are only a fraction of the radiation people are exposed to from natural background sources, such as cosmic radiation and radionuclides in the ground. In fact, all areas except for the sternum received less than 2 percent of annual background radiation dose.

Measured dose to the bridge of the eye and umbilicus was negligible, indicating no increased risk to the patient of cataracts or interference with normal embryonic development in early pregnancy.

"The risk of cancer induction at these low levels is indistinguishable from background incidence of cancer due to other sources," Dr. Chetlen said.

The findings are particularly important in light of a recent increase in the incidence of thyroid cancer, one of the most radiosensitive of all cancers. The number of thyroid cancer diagnoses in women nearly doubled from 2000 to 2008, leading some to suspect that mammography may be a contributing factor and that women should wear lead thyroid shields during exams, an idea that Dr. Chetlen and other mammography experts strongly discourage.

Based on the extremely low scatter radiation dose to the thyroid -- equivalent to just a few minutes of background radiation -- thyroid shields are unnecessary during mammography. In addition, the researchers warn that use of thyroid shields could result in an increased radiation dose to patients.

"A thyroid shield gets in the way of the exam and can actually cause an increase in radiation dose by necessitating repeat exams," Dr. Chetlen said.

Dr. Chetlen also pointed out that the thyroid gland is far less radiosensitive after age 30. The American Cancer Society and other organizations recommend that women have mammography screening once every year, beginning at age 40.

"In the age group eligible for screening, the thyroid gland is not very radiosensitive," Dr. Chetlen said.

Coauthors are Steven King, M.S., Karen Brown, C.H.P., D.A.B.R., Brian Lorah, Susann Schetter, D.O., Claudia Kasales, M.D., Shelley Tuzzato, R.T.R.M., and Shelly Rambler, R.T.R.M. 


Note: Copies of RSNA 2012 news releases and electronic images will be available online at beginning Monday, Nov. 26.

RSNA is an association of more than 50,000 radiologists, radiation oncologists, medical physicists and related scientists, promoting excellence in patient care and health care delivery through education, research and technologic innovation. The Society is based in Oak Brook, Ill. (

Editor's note: The data in these releases may differ from those in the published abstract and those actually presented at the meeting, as researchers continue to update their data right up until the meeting. To ensure you are using the most up-to-date information, please call the RSNA Newsroom at 1-312-949-3233.

For patient-friendly information on mammography, visit


  • Radiation dose to areas of the body near the breast during mammography is very low.
  • Researchers measured the dose received by the thyroid gland, salivary gland, sternum, uterus and the lens of the eye during screening digital mammography.
  • Thyroid shields are unnecessary during mammography and could actually result in an increased radiation dose to patients.

SOURCE Radiological Society of North America (RSNA)

About PR Newswire
Copyright © 2007 PR Newswire. All rights reserved. Republication or redistribution of PRNewswire content is expressly prohibited without the prior written consent of PRNewswire. PRNewswire shall not be liable for any errors or delays in the content, or for any actions taken in reliance thereon.

Latest Cloud Developer Stories
@ThingsExpo has been named the Top 5 Most Influential Internet of Things Brand by Onalytica in the ‘The Internet of Things Landscape 2015: Top 100 Individuals and Brands.' Onalytica analyzed Twitter conversations around the #IoT debate to uncover the most influential brands and i...
In the 21st century, security on the Internet has become one of the most important issues. We hear more and more about cyber-attacks on the websites of large corporations, banks and even small businesses. When online we’re concerned not only for our own safety but also our privac...
"We've discovered that after shows 80% if leads that people get, 80% of the conversations end up on the show floor, meaning people forget about it, people forget who they talk to, people forget that there are actual business opportunities to be had here so we try to help out and ...
There is growing need for data-driven applications and the need for digital platforms to build these apps. In his session at 19th Cloud Expo, Muddu Sudhakar, VP and GM of Security & IoT at Splunk, will cover different PaaS solutions and Big Data platforms that are available to ...
Join Impiger for their featured webinar: ‘Cloud Computing: A Roadmap to Modern Software Delivery’ on November 10, 2016, at 12:00 pm CST. Very few companies have not experienced some impact to their IT delivery due to the evolution of cloud computing. This webinar is not about de...
Subscribe to the World's Most Powerful Newsletters
Subscribe to Our Rss Feeds & Get Your SYS-CON News Live!
Click to Add our RSS Feeds to the Service of Your Choice:
Google Reader or Homepage Add to My Yahoo! Subscribe with Bloglines Subscribe in NewsGator Online
myFeedster Add to My AOL Subscribe in Rojo Add 'Hugg' to Newsburst from CNET Kinja Digest View Additional SYS-CON Feeds
Publish Your Article! Please send it to editorial(at)!

Advertise on this site! Contact advertising(at)! 201 802-3021

SYS-CON Featured Whitepapers